Physical |
Dimensions |
7” (H) x 17” (W) x 19.6” (D) |
(177.8 mm x 431.8 mm x 497.8 mm) |
Weight | Approx 44 lbs (20kg) |
Power Supply | Input | 100 - 240V VAC 50/60 Hz PFC, auto switching |
Cooling | | Two 120 mm front accessible fans |
One fan mounted in power supply |
One internal fan |
Processor System | CPU | 2 X Intel Xeon quad-core (E5335@ 2.0 GHz or E5345@ 2.33 GHz) with 8MB L2 cache, 1333 MHz FSB |
Chipset | Intel 5000X |
Memory | 4 channel - 8 Slots, DDR2-667 Fully Buffered DIMM => Up to 32 GB |
Video Output | | One VGA, One DVI-I |
Front I/O | Switches | Power |
LEDs | Power on, Hard Disk Activity, Ethernet Activity |
USB | One front-mount USB 2.0 |
Rear I/O | Keyboard | PS/2 |
Mouse | PS/2 |
Serial | Two 9-pin D-SUB Connectors |
Parallel | None |
USB 2.0 | One front, four rear |
Audio | AC 97 three 3.5mm stereo connectors |
Ethernet | 2 x Gbe (RJ45) |
Drives | 5.25” | 1 - populated with CD-ROM/DVD-RW IDE Drive, front accessible |
3.5” | 3 bays for SATA2, front accessible |
I/O Slots | PCIe x16 | 1 |
PCIe x8 | 1 |
PCIe x4 | 1 |
PCI-X 100 | 2 |
Environment | Temperature | Operating: +5º C to +45º C ambient temperature, Derated by 2º C per 1000 feet (300 meters) over 6600 ft (2000 meters) with sufficient airflow to keep within the temperature specifications. Operation above +30º C reduces the maximum operational relative humidity. |
Non-Operating: -30º C to +70º C, 5º C per minute maximum excursion gradient |
Relative humidity | Operating: 20% to 95% at maximum 29.4º C wet bulb (non-condensing) |
Non-operating: 5% to 95% at maximum 29.4º C wet bulb (non-condensing) |
Packaged: 5% to 95% at maximum 40º C wet bulb (non-condensing) |
Altitude | -30 to +4000m |
Acoustic Noise | Operating: 48dBA at 1m, +25º C, sea-level, full workload |
Shock | Operating: 1G, 11ms, half-sine |
Non-Operating: 30G,11 ms, square wave |
Vibration | Operating: 0.2g, 5-500Hz, sine 0.27 grms 5-500Hz, sine |
| Non-Operating: 2.2 grms, 5-500 Hz, random |
Regulatory | Emissions | Radiated emissions (EMC) 1 Operating CISPR 22: 1998, Class A, with no testing on the power port |
Conducted emissions Operating IEC 1000-4-6/EN61000-4-6:1995, performance criteria B |
Safety | Ul/cUL UL60950 |
EN60950 (CB REPORT) |
CE Mark |