Procelerant RMS420-5000XI

19-inch 4U Rack Mount Server

Product Description


The Procelerant RMS420-5000XI Rack Mount Server combines very high compute performance with PCI-Express (PCIe) x16 connectivity for high performance graphics cards. This combination is ideally suited for applications such as medical and military imaging, signal processing, 3D and 4D graphics display and test and measurement systems. These applications generally require extensive signal processing and results are often presented on one or more high resolution graphic displays. Customers can use the RMS420-5000XI server as a high performance compute platform, a high performance display platform, or both. The RMS420-5000XI chassis is 4U (7 inches) tall and 20 inches deep and provides sufficient space, power and cooling for high performance graphics cards in a minimal footprint.

Specifications

PhysicalDimensions7” (H) x 17” (W) x 19.6” (D)
(177.8 mm x 431.8 mm x 497.8 mm)
WeightApprox 44 lbs (20kg)
Power SupplyInput100 - 240V VAC 50/60 Hz PFC, auto switching
OutputTBD
CoolingTwo 120 mm front accessible fans
One fan mounted in power supply
One internal fan
Processor SystemCPU2 X Intel Xeon dual-core (5140) with 4MB L2 cache, 1333 MHz FSB
ChipsetIntel 5000X
Memory4 channel - 8 Slots, DDR2-667 Fully Buffered DIMM => Up to 32 GB
Video OutputTBD
Front I/OSwitchesPower
LEDsPower on, Hard Disk Activity, Speaker Activity
USBOne front-mount USB 2.0
Rear I/OKeyboardPS/2
Mouse PS/2
Serial1 9-pin D-SUB Connector
ParallelNone
USB 2.0One front, four rear
AudioAC 97 three 2.5mm stereo connectors
Ethernet2 x Gbe (RJ45)
Drives5.25”1 - populated with CD-RW/DVD-ROM IDE Drive, front accessible
3.5”3 bays for SATA2, front accessible
I/O SlotsPCIe x161
PCIe x81
PCIe x41
PCI-X 1001
EnvironmentTemperatureOperating: +5º C to +45º C ambient temperature, Derated by 2º C per 1000 feet (300 meters) over 6600 ft (2000 meters) with sufficient airlfow to keep within the temperature specifications. Operation above +30º C reduces the maximum operational relative humidity.
Non-Operating: -30º C to +70º C, 5º C per minute maximum excursion gradient
Relative humidityOperating: 20% to 95% at maximum 29.4º C wet bulb (non-condensing)
Non-operating: 5% to 95% at maximum 29.4º C wet bulb (non-condensing)
Packaged: 5% to 95% at maximum 40º C wet bulb (non-condensing)
Altitude-30 to +4000m
Acoustic NoiseOperating: 48dBA at 1m, +25º C, sea-level, full workload
Shock Operating: 1G, 11ms, half-sine
Non-Operating: 30G,11 ms, square wave
VibrationOperating: 0.2G, 5-500Hz, sine
Non-Operating: 0.001g2/Hz at 5Hz sloping to 0.01g2/Hz at 20-500 Hz
RegulatoryEmissionsRadiated emissions (EMC) 1 Operating CISPR 22: 1998, Class B, with no testing on the power port
Conducted emissions Operating IEC 1000-4-6/EN61000-4-6:1995, performance criteria B
SafetyUl/cUL UL60950
EN60950 (CB REPORT)
CE Mark